TitusHVAC
TitusHVAC
  • 439
  • 1 979 920
Titus Apure Video
FL-10LED - Flowbar with Lighting
Переглядів: 240

Відео

Titus Return Canopy (RCP)
Переглядів 777Рік тому
Keep private conversations private with the Titus Return Canopy (RCP). The Return Canopy is an easy-to-install accessory for return grilles that reduces crosstalk noise between private offices and conference rooms by becoming a lined, acoustical “shield”.
Terminal Unit Sizing
Переглядів 2,5 тис.Рік тому
Terminal Unit Sizing
TRM Surface Mounting IOM
Переглядів 1,5 тис.2 роки тому
The TRM Installation video provides insight into how this addition can assist with several diffusers for a hard ceiling applications.
CT Concealed Fastening
Переглядів 2,8 тис.2 роки тому
CT Concealed Fastening IOM showcases the proper way to install the CT Concealed Fastening product.
ML Border 2A (Concealed Fastening)
Переглядів 4,7 тис.3 роки тому
The Titus ML Modulinear diffuser is a high performance, high quality linear slot diffuser. The Border 77 option is an architectural appealing linear product that blends seamlessly into ceilings.
FL Border 77 IOM (Concealed Fastening)
Переглядів 7 тис.3 роки тому
The FlowBar Border 77 (Concealed Fastening) IOM shows the steps on how to install the unit in the ceiling. The clean look and architecturally appealing appearance after installation is what designers need to add elegance to a project.
ML Border 22 IOM
Переглядів 5 тис.3 роки тому
The Titus ML Modulinear diffuser is a high performance, high quality linear slot diffuser. The Border 22 option is an architectural appealing product that blends seamlessly into ceilings leaving only the slot visible.
Understanding TU Acoustics Webinar
Переглядів 1,5 тис.3 роки тому
Understanding TU Acoustics Webinar
THRC Webinar
Переглядів 8483 роки тому
The THRC webinar reviews the operation and best applications for this product to improve indoor air quality in occupied spaces.
Fan Coils 101 Webinar
Переглядів 2,8 тис.3 роки тому
This webinar provides a great background on fan coil products
THRC - HEPA Room Air Cleaner
Переглядів 1,4 тис.3 роки тому
The Titus HEPA Room Cleaner (THRC) is the ideal solution to improve indoor air quality by providing continuous filtration within the space.
Chilled Beams to Reduce or Eliminate Reheat
Переглядів 2,1 тис.3 роки тому
Chilled Beams to Reduce or Eliminate Reheat
Air Distribution Design for Laboratories
Переглядів 4,1 тис.3 роки тому
The Air Distribution Design for Laboratories Webinar discusses lab basics, ventilation requirements and fume hoods
CT Border 22 IOM
Переглядів 3,4 тис.3 роки тому
This video shows the process to install the CT Border 22 product. After installation, this linear unit blends seamlessly into the project leaving only the linear bars visible.
Air Distribution for Healthcare Facilities
Переглядів 2,8 тис.3 роки тому
Air Distribution for Healthcare Facilities
Designing and Retrofitting HVAC Systems to Limit the Spread of Transmission
Переглядів 2,2 тис.3 роки тому
Designing and Retrofitting HVAC Systems to Limit the Spread of Transmission
Designing HVAC Systems with VAV Diffusers
Переглядів 4,6 тис.4 роки тому
Designing HVAC Systems with VAV Diffusers
HVAC in Security Applications
Переглядів 7614 роки тому
HVAC in Security Applications
RadiaTec Diffuser Smoke Demonstration
Переглядів 4 тис.4 роки тому
RadiaTec Diffuser Smoke Demonstration
Applied Psychrometrics Webinar
Переглядів 11 тис.4 роки тому
Applied Psychrometrics Webinar
HVAC in Security Applications
Переглядів 6844 роки тому
HVAC in Security Applications
Displacement for Schools (AIA Certified)
Переглядів 9494 роки тому
Displacement for Schools (AIA Certified)
FlowBar Border 22 IOM
Переглядів 29 тис.4 роки тому
FlowBar Border 22 IOM
Titus Timeout Podcast - Water Flow Fundamentals
Переглядів 1,9 тис.4 роки тому
Titus Timeout Podcast - Water Flow Fundamentals
Titus Timeout Podcast - UFAD Characteristics and Challenges
Переглядів 4734 роки тому
Titus Timeout Podcast - UFAD Characteristics and Challenges
Titus Timeout Podcast - Constant Volume Regulators
Переглядів 1,4 тис.4 роки тому
Titus Timeout Podcast - Constant Volume Regulators
Titus Timeout Podcast - Ceiling's Effect on Diffuser Throw
Переглядів 1,6 тис.4 роки тому
Titus Timeout Podcast - Ceiling's Effect on Diffuser Throw
Titus Timeout Podcast - Fan Terminal Induction Ports
Переглядів 3934 роки тому
Titus Timeout Podcast - Fan Terminal Induction Ports
Titus Timeout Podcast - Water Coil Design Rules of Thumb
Переглядів 18 тис.4 роки тому
Titus Timeout Podcast - Water Coil Design Rules of Thumb

КОМЕНТАРІ

  • @user-wl5ld6qe7u
    @user-wl5ld6qe7u 15 годин тому

    I saw these vents in Ontario School Gyms

  • @hpzen8371
    @hpzen8371 3 дні тому

    Nice video Where i can download this excel

  • @HawkGTboy
    @HawkGTboy 7 днів тому

    So... how does this differ from the ML series?

  • @arjunshetty7612
    @arjunshetty7612 26 днів тому

    Solar decathlon brought me here

  • @user-lv4fz9hu6u
    @user-lv4fz9hu6u Місяць тому

    Very interesting

  • @erikyoung256
    @erikyoung256 Місяць тому

    Wonderful tutorial!

  • @yupaul8808
    @yupaul8808 Місяць тому

    Hi, may I ask why there is no need to add sensible load from people load, equipment and light load when calculating the sensible load?

  • @user-re9gj2cz8d
    @user-re9gj2cz8d 2 місяці тому

    U r baddass

  • @aircontrolserviceshotsprin1707
    @aircontrolserviceshotsprin1707 2 місяці тому

    This is the best information about why the air blows out sometimes on a series VAV box.

  • @michaelcollins8690
    @michaelcollins8690 2 місяці тому

    This doesn't look like it has a lot of light output. Doesn't really seem feasible as a lighting option.

  • @paxamdg2712
    @paxamdg2712 3 місяці тому

    thanks for the explanation! This helps very much! Do you have a video showing how you can tell if you have a 2 pipe or 4 pipe system?

  • @jollyscaria1922
    @jollyscaria1922 4 місяці тому

    Thankyou gues guied for welcome gues charted psy charted humidity thi..when the atmospheric air temperature increase the flow from air bodey to thesurrouding airdecreasses theheatflow furtherslowdown whentherelative .humidity ormosisstur contentof airincreasebecauseofslow ..evaportionofsweat fromthe bodeytempertature andrelarivehumiditeyof airarerhetwofactrsrelated to humancomfortincrease we feelhottemprure to same thithe dreeof discompfortedof aveegeunduvidualdue to at mosspher air ambeunt.)airtempwrureandrelative humidity ok

  • @uzumakinaruto-oq2mq
    @uzumakinaruto-oq2mq 4 місяці тому

    How do I come out with min and mx cfm numbers in vav box to specific room. Any answers would be great. At work place my Co worker keep changing the cfm without fixing the heating and colling problem. The original numbers are lost. Thanks in advance.

  • @wstt4
    @wstt4 5 місяців тому

    Is a plenum box needed for the supply side of AC or could metal Y’s be used? About 10’ from my handler is a plenium box that comes in with a big foil duct (maybe 16”) and exits the box at a right angle and exits with 3 different sized foil ducts (10”, 6” and 4”). Couldn’t i just use a Y into another Y to keep the air flow running straighter instead of a right angle and eliminate the box? I assume making right angles slows air flow. (The rooms with the 6” and 4” ducts don’t get as cool. I Was going to install in line booster fans for them too.). (Hawai’i so AC only, no heat).

  • @user-wd8pz6be8c
    @user-wd8pz6be8c 6 місяців тому

    Greqt presentation. Easy to understand. May I have soft copy. Thanks

  • @aircontrolserviceshotsprin1707
    @aircontrolserviceshotsprin1707 6 місяців тому

    Great video you explain this stuff so well!

  • @lindasun8366
    @lindasun8366 7 місяців тому

    How much more it costs compare to conventional diffuser?

  • @Polden_
    @Polden_ 8 місяців тому

    These units are wild lmao

  • @M-Cycle
    @M-Cycle 8 місяців тому

    Do you have a high temperature psychrometric chart? For temperature 350F/175C, for example, or almost twice a boiling point of water. We need high temp chart for M-Cycle. Would you like to see real breakthrough psychrometric chart with elegant explanation and whiteboard animated drawings? ua-cam.com/video/NzdNwKBVXT8/v-deo.html

  • @gavincw4195
    @gavincw4195 8 місяців тому

    So in open plenum systems is it just the AHU return fan sucking all the ambient air in the general direction of the AHU just more slowly than ducted returns?

    • @TitusHVAC
      @TitusHVAC 8 місяців тому

      Yes, open plenum systems are only ducted on the Supply through which the conditioned air is delivered to the occupied space. The Return side of the unit is open to the plenum above the ceiling grid and pulls air from the surrounding plenum space. This means that the HVAC equipment will need a filter on the unit directly at the return to filter the plenum air. Because the Return side of the unit is open to the general air space in the plenum, the air velocity near the HVAC equipment will be lower than the velocity traveling through Return ductwork. However having the Return open to the plenum space rather than ducted means the motor will work against lower ESP than a ducted Return system. For additional questions on this topic contact specialtyprod@titus-hvac.com.

    • @gavincw4195
      @gavincw4195 8 місяців тому

      @@TitusHVAC thank you so much 🙏

  • @FernandoGomez-zo1bz
    @FernandoGomez-zo1bz 8 місяців тому

    Thank you NOW I HAVE LET THE GC KNOW HE NEEDS TO FRAME OUT THE SLOT FIRST.

  • @michaelandrewhart7830
    @michaelandrewhart7830 10 місяців тому

    perfect thank you

  • @metallidome
    @metallidome 10 місяців тому

    Question, @3:24 you say that you don't want to run both coils at the same time, but earlier the discussion was about preheat vs reheat. ...Aren't the heating coils running concurrently with cooling in both scenarios? Thank you

    • @TitusHVAC
      @TitusHVAC 10 місяців тому

      In preheat, very cold, possibly subfreezing air is being drawn into the system and must be heated before it can be used, so only the heating coil is being used. And reheat may be required if high dehumidification results in lower than normal cooling temperatures. This of course is to be avoided if at all possible, because it results in simultaneous heating and cooling.

    • @metallidome
      @metallidome 10 місяців тому

      @@TitusHVAC Thank you.

  • @yokeleetan8525
    @yokeleetan8525 10 місяців тому

    Atually the required air flow to create pressure differential is dependent on the air flow across the doors. Thus door size and leakage round the door is important.

  • @abdoulyaya4711
    @abdoulyaya4711 10 місяців тому

    Apart from my mum this lady is the best

  • @69Crimthann
    @69Crimthann 10 місяців тому

    I am grateful of the explanation of the thermal diffuser near the 9:00 it really cleared up the instructions, at least for me. Thank you

  • @solomongoderdzishvili7273
    @solomongoderdzishvili7273 11 місяців тому

    Sorry what is different between total and outdoir ACH?

  • @jamesdriskill5784
    @jamesdriskill5784 11 місяців тому

    Well done

  • @eng.alimostafa-medical
    @eng.alimostafa-medical 11 місяців тому

    please can i get this presntation?

  • @joseluischavezavina4457
    @joseluischavezavina4457 Рік тому

    Good explanation

  • @lambon123
    @lambon123 Рік тому

    Thank you great video

  • @lambon123
    @lambon123 Рік тому

    Thank you

  • @maciejtanski5302
    @maciejtanski5302 Рік тому

    My professor couldn't explain it to me within half an hour, and here is 7 minute video and i understand everything.

  • @skesd
    @skesd Рік тому

    hepa fan filter unit

  • @udaynataraaj2390
    @udaynataraaj2390 Рік тому

    Ok

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 Рік тому

    Thank you for sharing this video.

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 Рік тому

    Thank you for sharing this video.

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 Рік тому

    Thank you for sharing this video.

  • @eulaliorodriguez5325
    @eulaliorodriguez5325 Рік тому

    Thank you for sharing this video.

  • @edwinhenriquez4638
    @edwinhenriquez4638 Рік тому

    I ONLY LIKE YOUR DRAWINGS THE OTHER ONES WERE FUCKED UP

  • @Gspot1012
    @Gspot1012 Рік тому

    Great break down.homie

  • @pops1pops178
    @pops1pops178 Рік тому

    Question do you need filter in that handler because the return air has a filter

    • @TitusHVAC
      @TitusHVAC Рік тому

      Although it is sometimes desirable to filter return air at a return air grille, it is standard practice to filter all air at the air handler. This is necessary to keep the air handler coils clean.

  • @cesargastonherrerabohorque4294

    Amazing video!

  • @InstikMeatSlicer-fx6ez
    @InstikMeatSlicer-fx6ez Рік тому

    Thanks very informative.

  • @InstikMeatSlicer-fx6ez
    @InstikMeatSlicer-fx6ez Рік тому

    Thank you very informative.

  • @eugeneb3682
    @eugeneb3682 Рік тому

    Romans8:31 if God is for us who can be against us?

  • @MA-em7ln
    @MA-em7ln Рік тому

    thank you, i am studying for my cih exam and this is exactly what I needed to understand these curves

  • @keonnoh9409
    @keonnoh9409 Рік тому

    Thank you so much for making it clear!!!

  • @rbnjr
    @rbnjr Рік тому

    Where i live heat and humidity are kept outside with a large HVAC system, i only want to infuse some fresh air into it. A ERV seems overly complicated and expensive. there is a way to keep the heat outside and bring in fresh air. It has to do with where the fresh air is being drawn in. I am trying to design a system that is much simpler and still provides exactly what i want.

    • @TitusHVAC
      @TitusHVAC Рік тому

      As I understand, your existing HVAC system purely cools/heats and recirculates indoor air. As such you have no real need for an ERV. If that is the case, you could simply introduce fresh (outside) air without tempering it, but doing so we increase the cooling/dehumidifying and heating loads your existing HVAC system has to handle. If you are comfortable that it is capable of handling the increased loads that is one option. However, you might you will also need to exhaust a similar volume of the room air as that outside air you brought in. You might consider adding a plate type heat exchanger serving the outside and exhaust air streams to minimize the effects on your existing HVAC system.

  • @AlexandraOlivares-bg4fx
    @AlexandraOlivares-bg4fx Рік тому

    Post one for Return Linear diffusers with no plenum, to be hold by the drywall ceiling frame